Product

DC-AC Energy Management Solutions

DC-AC Energy Management Solutions

150W up to 5000W, CPU controlled inverter with charger ,Built-in AVR module saving hundreds of USD of AVR kit

Description

Built-in AVR supports 100% protection, 150V~300V wide range
Intelligent Inverter with Auto-Transfer Switch and 20A charger circuit
• For heavy-duty power back-up system – UPS with big power
• Unique soft start
• Automatic fan operation
• Auto-detecting wrong battery
• Output short circuit protection
• Battery low pre-alarm
• Batter low alarm & shut down
• Over load pre-alarm
• Over load alarm and shut down
• Over heat pre-alarm
• Over heat alarm & shut down
Specification
Specifications
OUTPUT POWER CONTINUOUS POWER 150W up to 5000W
SURGE POWER 300W up to 10000W
STANDBY CURRENT DC 12V < 0.1.1A
DC 24V < 1A
INPUT VOLTAGE DC12V : 10V~15V
DC24V : 20V~30V
OUTPUT VOLTAGE AC 100V, 110V, 120V, 220V, 230V, 240V
OUTPUT WAVEFORM Modified Sine Wave
EFFICIENCY > 85%
※ INITIAL CHECKING AUTO-DETECTING WRONG BATTERY CONT. ex. 12V / 24V
※ OUTPUT REGULATION ± 5% INTELLIGENT PWM
※ OUTPUT FREQUENCY 50Hz, 55Hz, 60Hz CRYSTAL CONTROLLED.
※ COOLING AUTO-OPERATION FAN
※ OUTPUT SHORT OUTPUT SHORT CIRCUIT PROTECTION
※ LOW BATTERY < 10.5V or 21.5V ± 0.5V PRE-ALARM
< 9.5V or 20V ± 0.5V SHUT DOWN & ALARM
※ OVER HEATING > 60℃ PRE-ALARM
> 65℃ SHUT DOWN & ALARM
※ OVER LOAD > 5000W PRE-ALARM
> 5300W SHUT DOWN & ALARM
BATTERY POLARITY REVERSE BY FUSE
FUSE DC 12V : 30A * 24PCS
DC 24V : 15A * 24PCS
AC OUTLET (U) 3 AC OUTLETS
(E) 2 AC OUTLETS
※ BATTERY CHARGER AUTO-INDICATING FULL BATTERY
※ CHARGER CIRCUIT DC 12V : CONTINUOUS 20A
DC 24V : CONTINUOUS 10A
※ AUTOMATICAL SWITCH AC LINE → INVERTER
INVERTER → AC LINE
※ TRANSFER TIME AC LINE → INVERTER < 16ms
INVERTER → AC LINE < 20ms
 
Application Examples, Have a Idea ? ask us today for the Free design